| No. | Device Name | Picture | Index | Use |
|---|---|---|---|---|
| 1 | Electronic universal testing machine | ![]() |
Maximum tension: 2000KN
|
Mechanical properties of stretching, bending, compressive strength test |
| 2 | Heat aging box | ![]() |
Temperature: -70 ~ 150 ℃
|
High and low temperature heat aging performance test |
| 3 | UV aging box | ![]() |
Temperature: 10 ~ 70 ℃
|
UV aging tests |
| 4 | Salt spray aging test machine | ![]() |
Test temperature: <63 ℃
|
Anti-aging properties of salt spray corrosion test |
| 5 | High temperature chamber | ![]() |
Maximum temperature: 500 ℃
|
High Temperature Performance Test |
| 6 | Resistance Tester | ![]() |
Resistance: 103-1012 Ohm
|
Resistance Test |
| 7 | X-ray nondestructive testing | ![]() |
Field: 100mm
|
NDT |
| 8 | Ultrasonic flaw detector | ![]() |
Detection range: 0.1-8000mm
|
NDT |
| 9 | Rockwell hardness | ![]() |
Digital
|
Hardness Testing |
| 10 | Universal friction and wear tester | ![]() |
Test force: 10-1000N
|
Friction and wear properties |
| 11 | Electro-hydraulic servo fatigue testing machine | ![]() |
Maximum load: ± 1000KN
|
Dynamic and static mechanical properties |
| 12 | Rotating bending fatigue testing machine | ![]() |
Runout: ≤0.01mm
|
Bending fatigue test |
| 13 | High-frequency fatigue testing machine | ![]() |
Maximum load: 500KN
|
Fatigue characteristics of the sample under tension and compression and alternating flowers and the sine wave |
| 14 | Electronic high-temperature creep rupture strength testing machine | ![]() |
Maximum load: 100KN
|
High temperature creep relaxation tests |
| 15 | Drop hammer impact test machine | ![]() |
Maximum impact energy: 30000J
|
Impact Performance Test |
| 16 | Low temperature impact test instrument | ![]() |
Temperature range: 30 ~ -60 ℃
|
|
| 17 | Thermal Mechanical Analyzer | ![]() |
temperature range:
|
Thermo-mechanical properties of materials |
| 18 | Dynamic Mechanical Analyzer | ![]() |
Frequency Range:
|
Tg test material |
| 19 | Laser thermal conductivity meter | ![]() |
temperature range:
|
Thermal diffusivity, thermal conductivity measurement |
| 20 | Dilatometer | ![]() |
temperature range:
|
Linear expansion coefficient measurement |
| 21 | Differential Scanning Calorimetry | ![]() |
temperature range:
|
Thermal performance |
| 22 | TGA | ![]() |
Resolution: 0.1 g
|
Thermal performance |
| 23 | Microscopic infrared absorption spectrometer | ![]() |
MCT single point detector: ≥7800-600cm-11
|
Particle and fiber analysis |
| 24 | Rotary flow analyzer | ![]() |
Frequency Range:
|
Rheological performance analysis |
| 25 | Elemental analyzer | ![]() |
Measuring range: C:0.03~20mg; H:0.03~3mg; N:0.03~2mg; S:0.03~6mg; O:0.03~2mg |
Content measurement sample CHNSO |
| 26 | Liquid X-ray diffractometer | ![]() |
High voltage stability: 0.005%
|
Microscopic observation |
| 27 | Nuclear magnetic resonance spectrometer | ![]() |
Time resolution: 12.5ns
|
Structural analysis of organic compounds |
| 28 | Fiber tensile tester | ![]() |
Load Range: 0 ~ 200 cN
|
Fiber strength, elongation test |